Known Limitations and Issues
The table below highlights known limitations or issues against the V4.5.1 VideoEdge Appliance and
the V4.5.1 VideoEdge Client. Known limitations and issues may exist from previous releases. Please
refer to the specific release for the appropriate information as well as the V4.5.1 VideoEdge release
notes.
VideoEdge Appliance
VideoEdge Appliance
Description
Suggested Work-Around
When a camera resolution is lowered from
D1 to QCIF, the clarity of the OSD text
decreases correspondingly.
For best results, use OSD with a camera resolution of
D1, a lower transparency, and an appropriate high
contrast color.
For analog cameras, you cannot directly
configure a MJPEG stream to be greater
than 12 FPS or 2CIF resolution.
Set both streams to MJPEG, 12 fps and 2CIF and click
apply. After clicking apply, configure one of the streams
to have a resolution greater than 2CIF and an FPS of
greater than 12.
When changing the OSD font for analog
cameras from ASCII to ASCII small when
three or more items are already present,
distortion may occur. This can manifest as
the repeating of an OSD item multiple
times down the screen.
When changing the OSD font for analog cameras,
proceed to remove the OSD item and then re-enter them
using the desired character settings.
Changing the time on the VE Appliance
could cause cameras to go offline and no
video can be viewed from them.
Restart the recorder.
When using a KVM, the Linux standard
GUI may not be displayed upon boot up
and then show only a command prompt.
Press <Ctrl><Alt><F2> to access the command line
prompt #. Proceed to edit the config file
/etc/X11/xorg.conf. Under the “Monitor” section, lower
the upper rant VertRefresh parameter to a lower value (if
it is 85, then change it to 75 or 60). Save the file and
then reboot the recorder.
After changing the clock or time zone, the
VE Appliance can stop behaving correctly.
After modifying the date/time or time zone, go to the
Advanced > Shutdown web page and select “Restart
NVR Services”.
Some combinations of OSD text and
backgrounds colors can cause the OSD
text for analog cameras to distort.
Decrease the transparency for the background to
improve the contrast on the OSD text for analog
cameras.
VideoEdge Client - update of ptz preset
setting is delayed in video pane display
Workaround is to wait until VideoEdge Client does an
update done in ~ 30 seconds.
VE Appliance - Inconsistent dwell times
when multiple tours ran on local analog
spot monitor
Workaround is to only have a single tour included with a
fixed view to either spot monitor(s) or VideoEdge Client.
Panasonic WC CS385 - G726 doesn't
play audio
No known workaround. G726 audio codec not supported
NVR 4.4 Bitrate changes i600 Minidome -
when lowering quality of CVBR reports
bitrate error on web GUI page
Ignore the error, move off the page and return and the
lower rate bitrate will be set