1691 CONNECTIONS
5
Code Output Connections - All Models
The 1691 Code Distribution Unit provides 64 code line outputs
from a single code line input.
Each of the 64 code line outputs is through individual external
connectors each with three output terminals for camera control
commands (camera pan/tilt/lens/preset/aux) to AD Manchester
Control Code units, such as camera site receivers.
Each of the three output terminals are designated B for black,
W for white, and S for shield.
B Connect a black code wire from the B terminal on the
1691 to the B terminal of a suitable Manchester Code
receiver (see Figure 3, Page 3, or Figure 4, Page 4).
W Connect the white code wire from the W terminal on
the 1691 to the W terminal of a suitable Manchester
Code receiver.
S Connect one end of the shield cable between the 1691
and the receiver to the S terminal. Connect the
opposite end of the shield cable to the S terminal of
the receiver.
NOTE: AD Receivers feature built-in termination on their
logic boards. Verify the termination requirements of
non AD units before completing the connections.
NOTE: Use 18 Awg, shielded, 2-wire cable, Belden 8760 or
equivalent for code line connections. The maximum
cable length is 5000 feet. For plenum wiring, use
Belden 88760.
NOTE: Tables One and Two (pages 6 and 7, respectively),
provide space to record basic connection information
between the 1691 Code Distribution Unit and up to 64
code receivers.
Daisy Chain Connection
Each code line can accommodate a maximum of three code-
controlled units in a “Daisy Chain” configuration of less than
500 feet.
NOTE: Terminate only the last unit on the code line in 120
ohms.
If additional equipment is required on a code line, or of longer
distances are involved, Code Distribution Units must be used.
Each code line can accommodate a maximum of three code
receivers in a “daisy chain” configuration of less than 5000
feet, as illustrated in Figure 5, below). The last unit in the
daisy chain must be terminated with a 1201/4 Watt resistor.
Figure 5 -- 1691 Daisy Chain Configuration
1691 Code Distributor
Code Receiver #1
Code Receiver #2
Code Receiver #3*
* = 120 Termination
B
W
S
B
W
S
B
W
S
SWB