UPGRADING THE RHODUL OUTDOOR HOUSING 8200-0324-01, REV. A
SERVICE GUIDE
9 of 9
Appendix C: Disassembling and
Reassembling the Strain Relief
Assembly (RHODUL-01/-02 only)
Removing PC board reveals the strain relief
assembly, Dismantle the assembly as follows:
Unscrew finger-tight machined cap and remove
bushing and strain relief ring from assembly. If cap
is too tight to remove by hand, use 1-1/8" open-
ended wrench or pliers to remove. Discard the
bushing and strain relief to allow for proper
ventilation.
Strain relief assembly (discard bushing and
strain relief)
Appendix D:
Testing Camera Function
Check LEDs on environmental board to verify
power and data are reaching outdoor housing.
a. Press and hold switch SW2 and observe green
(ac power) and yellow (comm.) LEDs. Green
LED glows steadily and yellow LED glows
steadily (RS422) or blinks (SensorNet).
b. For RS422 data, press and hold data test
switch SW1 and observe nearby red and green
LEDs; they indicate the following:
Constant green,
Blinking red
RS422 line is
correctly wired.
Constant green,
No red
RS422 “Data In –” is
shorted to ground.
Constant red,
Blinking green
“Data In + /–” wires
are reversed.
Blinking red,
Green off
“Data In +” is shorted
to ground.
Both LEDs off
“Data In +/–” wires
are shorted or open.