SPEEDDOME ULTRA VII CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0184-01, REV. A1)
17 of 41
4. Connect the alarm output cable, if used,
to the P3 connector.
Pin Color Designation
1 12Vdc (100mA max.)
2 12Vdc (100mA max.)
3 Output P0 (40mA sync. max.)
4 Output P1 (40mA sync. max.)
5 Output P2 (40mA sync. max.)
6 Output P3 (40mA sync. max.)
7 — Ground
8 — Ground
5. Connect the alarm input cable, if used,
to the P4 connector.
Pin Color Designation
1 Alarm 3 input (3.5mA sink)
2 Alarm 2 input (3.5mA sink)
3 Alarm 1 input (3.5mA sink)
4 Alarm 0 input (3.5mA sink)
5 — Ground
6 — Ground
6. Connect power to P7 connector.
Pin Color Designation
1 Black 24 Vac
2 Red Ground
3 White 24 Vac
7. Reattach the I/O board.
8. Connect power to the base.
9. Check LEDs on the I/O board to verify power
and data are reaching the dome (Figure 16).
a. The green (ac power) LED glows steadily
when ac power is applied.
b. For Manchester or SensorNet: The yellow
(comm.) LED glows steadily (Manchester) or
blinks (SensorNet). If this LED is off, then
probably one or both communication wires
are open or both are shorted together.
For RS422: Press and hold data test switch
SW1 and observe nearby red (CR34) and
green (CR35) LEDs; they indicate the
following:
Constant green,
Blinking red
RS422 line correctly
wired.
Constant green,
No red
RS422 "Data In -"
shorted to ac ground.
Constant red,
Blinking green
"Data In +/ -" wires
reversed.
Blinking red,
Green off
"Data In +" shorted to
ac ground.
Both LEDs off
"Data In +/ -" wires
shorted or open.
Figure 16. Test switch/LEDs on I/O board
Comm. LED
Power LED
RS422 Test
Pushbutton
SW1
Red (CR34)
Green (CR35)
Green (CR33)
Yellow
(CR28)