SPEEDDOME ULTRA VII CAMERA DOME INSTALLATION AND SERVICE GUIDE (8200-0184-01, REV. A1)
8 of 41
Cable Requirements
Data Cable
The table below shows requirements for
SensorNet, RS422, and Manchester networks. For
more information about communication protocols
and cable networks, see Communication Protocols
and Cable Networks, 8000-2573-19.
Data cable requirements
SensorNet RS422 Manchester
Cable type 1
unshielded,
twisted
pair*
2
shielded,
twisted
pair*
1
shielded
twisted
pair**
Wire gauge 22 AWG 22 AWG 18 AWG
Connection Non-
polarized
Polarized Polarized
Max.
devices on
line
32 10 3
* Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables
must be used in indoor ceilings used for environ-
mental air return (called "other air space" in the
National Electrical Code). Order parts through
your distribution network.
Note: If you order cable from an outside
source, wire colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable
(non-plenum) cable is recommended. Plenum-
rated cables must be used in indoor ceilings used for
environmental air return (called "other air space" in
the National Electrical Code). Order
cable directly
from Belden by calling 1-800-235-3361.
Power Cable
For the camera dome to operate properly, line
voltage must not go below the worst-case low line
voltage shown in the following table. Make cable
lengths as short as possible to minimize affects of
low line voltages. As shown in the table, maximum
cable length depends on the Class 2 LPS (low
voltage) ac source (such as a J-box) and the worst-
case low line voltage. These lengths are for
Sensormatic composite cables, which use 18
AWG
ac power wires.
Note: Typically, distances are used that provide
a 15% margin between nominal and low line
conditions. For example, if the nominal voltage is
120Vac, restrict cable length to that associated
with 100Vac (0.85 x 120).
Worst-case ac line voltages
Indoor Dome
Worst-Case Meters
AC Power Source
Low Line V (Feet)
28 VA
117 600 (180)
Transformer
100 430 (130)
5604-0006-01 90 270 (80)
50 VA
117 600 (180)
Transformer
100 500 (150)
5604-0044-01 90 300 (90)
1-position SensorNet
117 700 (210)
RJ1SNUD
100 430 (130)
90 325 (100)
1-position SensorNet
117 700 (210)
RJ1SNUD-1
100 430 (130)
90 325 (100)
117 1000 (300)
6-position SensorNet
100 750 (230)
Indoor J-Box 90 530 (160)
RJ6SN
240 1000 (300)
200 750 (230)
180 530 (160)
10-Position RS422
117 900 (275)
Indoor 120V/60Hz J-Box
100 650 (200)
RJ860AP 90 430 (130)
10-Position RS422
240 900 (275)
Indoor 240V/60Hz J-Box
200 650 (200)
RJ860AP1 180 430 (130)
Universal Transformer
117 650 (200)
0300-0914-01
100 430 (130)
90 300 (90)
Universal Transformer
240 650 (200)
0300-0914-03
200 430 (130)
180 300 (90)