Using the Install/Removal
Tool
CAUTION: Do not use this tool to connect the
dome to the standard base.
Used only when the dome is connected to a base
having an I/O board, the RHIRT install/removal tool
eliminates the need for a ladder during routine
service. The tool can be used to:
· Detach skirt or bubble from housing, if used.
The skirt or bubble remains attached to the
housing during service.
· Connect/Disconnect dome from base with I/O
board.
· Reattach skirt or bubble.
Telescopic Pole Required to Use Tool
The tool attaches to a telescopic pole similar to the type
used to clean swimming pools. The pole should be 5
feet, 5 inches to 15 feet, 5 inches long and have a 1.170
-inch inside diameter to accept the 1.125 inch diameter
stem of the tool. If this pole cannot be obtained locally,
contact the following manufacturer:
Recreational Water Products
627 E. College Ave.
Decatur, GA 33030
Ask for product code 08140
UPC: 0-14746-58140-2
Procedure
Referring to Figure 19, maneuver the stem of the
tool into the top of the pole until it snaps in place.
TO ATTACH SKIRT OR BUBBLE:
Use tool to push up on bubble and to secure it in
place. Magnets secure the bubble. Lower pole.
TO DETACH SKIRT OR BUBBLE:
Lifting pole up at an angle, use one of the hooks on
tool to catch one of the notches at side of dome
and pull down. T-lanyard will prevent skirt or
bubble from falling.
TO CONNECT DOME:
1. Insert dome "eyeball down" into tool's
receptacle. Fins on dome mate with slots in tool.
Use fins to properly align dimple at top of dome
with label on tool.
2. Align label on tool with logo on I/O board in
base. Push dome up into place.
3. Turn dome clockwise until it clicks.
4. If power is applied, dome should begin its
"homing" routine.
5. Lower pole.
TO DISCONNECT DOME:
1. Raise pole and insert dome "eyeball down"
into tool's receptacle.
2. Fins on dome mate with slots in tool.
3. Turn dome counterclockwise until it unlocks.
4. Lower pole "vertically" to prevent camera dome
from falling out.
CAUTION: Turning pole horizontally as it is
lowered can cause camera dome to fall out of
tool and possibly break on floor.