4. Switch on the CPU. The LCD screen displays the
AD Welcome Screen (
Figure 10), followed by the
CPU Status screen, two examples of which are
shown in
Figure 11.
Figure 10. AD welcome screen
Figure 11. CPU status screen
or
Using an IP Address Assigned by the
Network DHCP Server
To set up the MegaPower CPU to obtain an IP
address from a DHCP server, do the following:
1. Connect a keyboard to an RS-232 port on the
MegaPower CPU. Ensure the baud rates match
for the keyboard and CPU port in use.
2. Use the following instructions to provide the key
sequences for each supported keyboard:
AD2088:
a. Place the keyboard in Menu Mode by turning
the keyswitch to MENU. The Camera field
LED on the keyboard should display P6.
b. Enter one of the following number sequences
for your MegaPower CPU installation:
Standalone MPCPU: Enter 100.
Dual MPCPU: Enter 100 for the selected
MegaPower CPU, or enter 101 for the
Standby MP CPU.
c. Press the ENTER key, which is located above
the joystick. “ENTER” is stenciled on the front
face of the key; the top of the key may be
labeled either PRESET or SHOT.
The Camera field LED on the keyboard will
only display 7P if the selected CPU is
accessed.
ADCC1100:
a. Place the keyboard in Program Mode by
clicking the tab in the middle of the lower part
of the screen).
Note: To display and enter Program Mode, you
must insert a Smartcard that has administrator
privileges.
b. Press the Matrix Menus softkey.
c. Enter one of the following number sequences
for your MegaPower CPU installation:
Standalone MPCPU: Enter 100.
Dual MPCPU: Enter 100 for the selected
MegaPower CPU, or enter 101 for the
Standby MP CPU.
d. Press the Enter softkey.
ADCC0200/0300:
Notes: In RS–232 mode, the ADCC0200
keyboard does not have matrix menu access
capabilities as indicated by the Access Denied
message if the following procedure is attempted.
a. Press and hold the Shift (
) button and then
press the Menu (
) button.
b. Enter one of the following number sequences
for your MegaPower CPU installation:
Standalone MPCPU: Enter 100.
Dual MPCPU: Enter 100 for the selected
MegaPower CPU, or enter 101 for the
Standby MP CPU.
c. Press Enter (
).
Note: Whenever scrolling to a different line
item on the LCD screen, you must press
twice to select the new item.
Note: To exit Program Mode, press and hold the
Shift (
) button, and then press the Clear ( )
button.
ADTTE:
a. Place the keyboard in Program Mode
(indicated by –P being displayed at the far right
of the LCD).
b. Press the Menu key. The LCD screen displays
P6 - M.
c. Enter one of the following number sequences
for your MegaPower CPU installation:
Standalone MPCPU: Enter 100