MEGAPOWER CPU 8200-0421-03, REV. G
ADMINISTRATOR’S GUIDE
40 of 82
Figure 80. Delete Rows dialog
4. Click Yes to delete the event timer definition or
No to close the dialog box without deleting the
definition.
Creating Alarm Monitor/
Contact Tables
Alarm Monitor/Contact Tables allow you to associate
alarm contacts with cameras or Salvos, Presets, and
auxiliaries. You can set the alarm dwell time,
auxiliary states, connections, and the locations of
each alarm contact.
Click on Alarms – Contact Definitions to begin. The
following screen appears (
Figure 81).
Figure 81. Alarms – contact definitions screen
To create Alarm Monitor/Contact Tables, complete
the following fields:
Contact No. – Determined by the following:
MPCPU port designation Alarms (1-1024),
Alarms (1025-2048), Alarms (2049-3072), or
Alarms (3073-4096), and either:
The physical contact point on the AD2096A
Alarm Interface Unit and the AD2096A DIP-
switch settings, or
The dome address and the AD2083-xx RS-422
Distributor’s DIP-switch setting for the Number
of Alarm Contacts per Dome
Camera or Salvo – Specifies the camera pseudo
number or Salvo to be called when the alarm
activates. If the Link field is set to Salvo or Salvo
Group Ack, the number in this field refers to the
Salvo number.
Preset or Pattern – Indicates a Preset (0-96) or a
Pattern number (0-3) assigned to the camera
number or Salvo selected above. Enter the
number of a Preset or Pattern for the
corresponding camera number or Salvo field as
follows:
Figure 82. Contact Definitions Preset or Pattern
Dropdown List
For a Preset number, enter a numeric value
into the Preset or Pattern field. Ensure there is
no prefix displayed as part of the numeric value
entered. If the “Pat” prefix is displayed, select
“General Preset Number” from the dropdown
list to remove it.
For a Pattern number, enter a numeric value,
and then select “Pattern Specific Number” from
the dropdown list. The numeric value entered
will now contain a “Pat” prefix.
(See the MegaPower CPU Operator’s Guide,
8200-0421-02, for more information on
Presets.)
Link – Allows linking of a contact definition to
another contact definition, salvo, or wired set of
alarm contacts. Linked options are:
No - Indicates that the alarm contact entry
either is not linked with another alarm contact
or is the last entry of a linked group of alarm
contacts.
Yes - Indicates that the alarm contact entry will
be linked to the next alarm contact entry
programmed into the system. A group of
contacts linked in this way emulates a system
Salvo (more than one camera action runs in
response to an alarm).
Salvo - Indicates that the alarm contact entry
will call a Salvo to a block of monitors.
Wired - Indicates that the alarm contact entry
will be linked to the following entry in a wired
set. A wired set is a set of alarm contacts.