NVR Failover
218 VideoEdge NVR 4.4 Installation and User Manual
Procedure 18-2
Configuring Failover Parameters
Step Action
1 Select Advanced from the main menu.
2 Select
Failover.
The Failover page opens.
3 Sele
ct the Advanced tab.
4 Edit the re
quired Failover parameters:
a Polling Interval - Clic
k Edit, enter the interval time in seconds and click Save.
b Retry Count - Clic
k Edit, enter the retry count and click Save.
c Config Update Interval - C
lick Edit, enter the interval time in seconds and click
Save.
- End -
Terminating Failover Mode When Primary NVR is Operational
After you have recovered the failed primary NVR, it will remain in an standby state until the
secondary NVR failover mode is terminated.
When you terminate Failover mode on the secondary NVR, it returns to monitoring the servers in
the monitoring list.
To terminate failover mode for a primary NVR you must terminate failover from the secondary NVR’s
Administration Interface, and not from the Administration Interface of any of the primary NVR.
Procedure 18-3
Terminating Failover Mode
Step Action
1 Select Advanced from the main menu.
2 Select
Failover.
The Failover page opens.
3 Click
Terminate Failover.
The secondary NVR returns to monitoring the server monitoring list.
- End -