NVR Failover
215
It is important to note when you are configuring storage for a secondary NVR, the storage
configuration must be able to support recording of any camera configurations set up on any of the
primary NVRs it is monitoring.
Note
For seamless playback on victor unified client the primary and secondary NVRs must all share the
same username and password.
The secondary NVR must have at least the same processing power as the largest primary NVR it
is protecting and must be licensed for at least as many cameras as the largest associated primary
NVR.
For VideoEdge Hybrid Appliances, the secondary NVR must have at least as many analog inputs
as
the largest primary NVR.
The network connection of the secondary N
VR should have the same capability as the network
connection from the primary NVRs to the client. If, for example, the secondary NVR is connected
through a lower bandwidth connection than the primary NVR, you will notice a difference in
performance when the secondary NVR is active if the primary NVR fails.
Failover Advanced Configuration
You can edit the default Failover Advanced configuration settings. The Failover Advanced
configuration settings dictate how often the secondary NVR polls the primary NVR to confirm its
current state.
There are three parameters which can be configured:
Polli
ng Interval - This is how often the secondary NVR checks the primary NVR. The Polling
Interval has a default of 10, this means the secondary NVR will check the primary NVR(s) every
10 seconds.
Ret
ry Count - This is the number of polling failures until the primary NVR is considered to be
inoperable and Failover should begin. The Retry Count has a default of 3, this means the
secondary NVR will try 3 times to check the status of the primary NVR before failover is initiated.
Conf
ig Update Interval -This is the interval of how often the secondary NVR downloads the
primary NVRs’ configuration. The Config Update Interval has a default value of 60, this means
the secondary NVR will check the configuration of the primary NVR(s) every 60 seconds.
Caution
The default settings for the Failover Parameters are recommended to provide the reliable operation of
the Failover function. Depending on the levels of traffic on your network you can try alternative settings. If
the secondary NVR fails to receive responses from the primary NVRs on the network (i.e. due to network
traffic), this may result in failover triggering unnecessarily.